簡要描述:
恒溫恒濕濾膜稱重系統新款亮點介紹記(ji)錄稱量(liang)(liang)(liang)(liang)結果,以2次稱量(liang)(liang)(liang)(liang)的(de)平(ping)均值作(zuo)為稱量(liang)(liang)(liang)(liang)結果。當(dang)同一(yi)采(cai)樣頭(tou)2次稱量(liang)(liang)(liang)(liang)中(zhong)的(de)質量(liang)(liang)(liang)(liang)差大(da)于0.20mg時(shi),可將相(xiang)應采(cai)樣頭(tou)再平(ping)衡至(zhi)少24h后稱量(liang)(liang)(liang)(liang);如果第二次稱量(liang)(liang)(liang)(liang)中(zhong)的(de)質量(liang)(liang)(liang)(liang)同上次稱量(liang)(liang)(liang)(liang)的(de)質量(liang)(liang)(liang)(liang)差仍大(da)于0.20mg,可將相(xiang)應采(cai)樣頭(tou)再平(ping)
產品時(shi)間:2024-04-22
產品型號:LB-350N
廠商性質:生產廠家
品牌 | 其他品牌 | 產地類別 | 國產 |
---|---|---|---|
應用領域 | 環保 |
恒溫恒濕濾膜稱重系統新款亮點介紹
選定己(ji)按(an) 8.2.1處理平(ping)衡(heng)后的(de)(de)采樣(yang)(yang)頭(tou),在恒溫恒濕設(she)備內(nei)(nei)用天(tian)平(ping)稱(cheng)(cheng)(cheng)重,每個樣(yang)(yang)品稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)2次(ci),每次(ci)稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)間(jian)隔應(ying)大于(yu)1h,2次(ci)稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)結果(guo)間(jian)*大偏差(cha)應(ying)在0.20mg以內(nei)(nei)。記錄稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)結果(guo),以2次(ci)稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)的(de)(de)平(ping)均值作為稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)結果(guo)。當同(tong)一(yi)采樣(yang)(yang)頭(tou)2次(ci)稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)中的(de)(de)質(zhi)量(liang)(liang)(liang)(liang)差(cha)大于(yu)0.20mg時,可將(jiang)相應(ying)采樣(yang)(yang)頭(tou)再(zai)平(ping)衡(heng)至(zhi)少(shao)24h后稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang);如(ru)果(guo)第二(er)次(ci)稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)中的(de)(de)質(zhi)量(liang)(liang)(liang)(liang)同(tong)上次(ci)稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)的(de)(de)質(zhi)量(liang)(liang)(liang)(liang)差(cha)仍大于(yu)0.20mg,可將(jiang)相應(ying)采樣(yang)(yang)頭(tou)再(zai)平(ping)衡(heng)至(zhi)少(shao)24h后稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang);如(ru)果(guo)第三次(ci)平(ping)衡(heng)后稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)的(de)(de)質(zhi)量(liang)(liang)(liang)(liang)同(tong)上次(ci)稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)的(de)(de)質(zhi)量(liang)(liang)(liang)(liang)差(cha)仍大于(yu)0.20mg,在確認平(ping)衡(heng)稱(cheng)(cheng)(cheng)量(liang)(liang)(liang)(liang)儀器和操作正確后,此樣(yang)(yang)品作廢。
什么是恒溫恒濕稱重系統
恒(heng)(heng)溫恒(heng)(heng)濕稱(cheng)(cheng)(cheng)(cheng)重系統(tong)是為滿足環(huan)(huan)保(bao)(bao)部標(biao)HJ836-2017、HJ618-2011和(he)HJ656-2013中規定(ding)的(de)(de)要(yao)求(qiu),在恒(heng)(heng)溫恒(heng)(heng)濕環(huan)(huan)境內(nei)放(fang)置高精(jing)度天(tian)平,將要(yao)稱(cheng)(cheng)(cheng)(cheng)量(liang)的(de)(de)樣(yang)(yang)(yang)品(pin)放(fang)入(ru)恒(heng)(heng)溫恒(heng)(heng)濕箱(xiang)體(ti)內(nei)平衡(heng)24小時后(hou)再進行稱(cheng)(cheng)(cheng)(cheng)量(liang)。解(jie)決了實(shi)驗(yan)室(shi)(shi)環(huan)(huan)境溫度濕度的(de)(de)變化對樣(yang)(yang)(yang)品(pin)稱(cheng)(cheng)(cheng)(cheng)重結果的(de)(de)影響,極大的(de)(de)提高了稱(cheng)(cheng)(cheng)(cheng)量(liang)樣(yang)(yang)(yang)品(pin)結果的(de)(de)準確(que)性,該產品(pin)也用于(yu)(yu)其它對稱(cheng)(cheng)(cheng)(cheng)量(liang)環(huan)(huan)境要(yao)求(qiu)較高的(de)(de)樣(yang)(yang)(yang)品(pin)稱(cheng)(cheng)(cheng)(cheng)量(liang)。無需額外建設(she)恒(heng)(heng)溫恒(heng)(heng)濕實(shi)驗(yan)室(shi)(shi)。多級防震技術(shu)及(ji)*的(de)(de)系統(tong)去(qu)耦設(she)計(ji),確(que)保(bao)(bao)精(jing)密電子天(tian)平不受微振(zhen)動(dong)干擾。該產品(pin)可廣泛應用于(yu)(yu)環(huan)(huan)境監(jian)測站(zhan),氣(qi)象監(jian)測站(zhan),科研和(he)第(di)三方(fang)檢(jian)測實(shi)驗(yan)室(shi)(shi)等領域。
相(xiang)關國家標準
恒溫恒濕濾膜稱重系統新款亮點介紹
HJ836-2017《固定污(wu)染源廢氣 低濃度顆粒物的測定重(zhong)量法》
HJ618-2011《環(huan)境(jing)空(kong)氣(qi)PM10和PM2.5的測定重量法》
HJ656-2013《環境空氣顆粒物(wu)(PM2.5)手(shou)工(gong)監測方法(fa) 重量法(fa) 技術規范》
電爐
1、爐膽材料:采用高(gao)鋁內(nei)膽,高(gao)溫(wen)爐上下左右(you)四(si)面發熱。
2、隔熱方法:保溫磚及(ji)保溫棉。
3、測(ce)溫(wen)口:熱電偶從爐體后上(shang)方進入。
4、接線柱(zhu)::發熱爐(lu)絲接線柱(zhu)位于爐(lu)體(ti)后下方位置(zhi)。
5、控制器:位于爐體下方,內置控制系(xi)統,補償導(dao)線連接(jie)爐體。
6、加熱元(yuan)件:高(gao)溫電阻(zu)絲。
7、功率:≥1000W;電源電壓:220V,50Hz。
油浴鍋
1、溫度(du)范圍:室溫-300℃。
2、精度:±0.1°C,均勻度:±0.1°C。
3、功率(lv):≥1500W,電源:220V 50Hz。
4、滿足土壤(rang)有機質測定要求(qiu)。